The exodraft chimney fan RSV is an exhaust fan created with a powerful vertical discharge.
The fan is placed above the chimney. A vacuum is created in the chimney and flue pipe. The chimney fan is suitable for all kinds of fuel but is especially ideal for solid fuel fireplaces, boilers, and stoves.
Product | Rev / min. | Voltage | Amp | kW | Weight | Capacity |
---|---|---|---|---|---|---|
RSV009 | 1400 | 1 x 230 V | 0,14 A | 0,05 | 13 kg | Up to 740 m³/h |
RSV012 | 1400 | 1 x 230 V | 0,35 A | 0,13 | 17 kg | Up to 1,600 m³/h |
RSV014 | 1400 | 1 x 230 V | 0,8 A | 0,16 | 24 kg | Up to 2,350 m³/h |
RSV016 | 1400 | 1 x 230 V | 1,8 A | 0,32 | 35 kg | Up to 3,400 m³/h |
RSV160 | 1400 | 1 x 230 V | 0,4 A | 0,04 | 12 kg | Up to 500 m³/h |
RSV200 | 1400 | 1 x 230 V | 0,4 A | 0,07 | 18 kg | Up to 1,100 m³/h |
RSV250 | 1400 | 1 x 230 V | 0,8 A | 0,16 | 27 kg | Up to 1,500 m³/h |
RSV315 | 1400 | 1 x 230 V | 1,8 A | 0,37 | 37 kg | Up to 3,000 m³/h |
RSV400 | 1400 | 1 x 230 V | 2,6 A | 0,60 | 47 kg | Up to 4,400m³/h |
RSV400 | 1720 | 3 x 230 V | 4,0 A | 0,75 | 52 kg | Up to 4,800 m³/h |
RSV450 | 1720 | 3 x 230 V | 6,5 A | 1,5 | 58 kg | Up to 7,300 m³/h |
The exodraft chimney fan type RS are exhaust fans developed to discharge smoke horizontally (sideways).
The chimney fan can be utilized for all kinds of fuels but is especially ideal for solid fuel fireplaces, boilers, and stoves.
The RS009-016 models come in a pair of versions: an octagonal mounting plate for steel chimneys and a square mounting plate for brick chimneys.
The chimney fan RS255 and RS285 come with a centrifugal impeller that contains aluminum blades that are curved-cast.
Product | Rev / min. | Voltage | Amp | kW | Weight | Capacity |
---|---|---|---|---|---|---|
RS009 | 1400 | 1 x 203 V | 0,3 A | 0,05 | 9 kg | Up to 1,000 m³/h |
RS012 | 1400 | 1 x 203 V | 0,3 A | 0,09 | 14 kg | Up to 2,250 m³/h |
RS014 | 1400 | 1 x 203 V | 0,6 A | 0,13 | 18 kg | Up to 3,100 m³/h |
RS016 | 1400 | 1 x 203 V | 1,2 A | 0,29 | 25 kg | Up to 3,750 m³/h |
RS255 | 1400 | 1 x 203 V | 0,4 A | 0,07 | 14 kg | Up to 1,200 m³/h |
RS285 | 1400 | 1 x 203 V | 0,8 A | 0,18 | 20 kg | Up to 1,850 m³/h |
The RSHT chimney fan is designed to operate under extreme conditions with very high flue gas temperatures.
The patented cooling wheel allows continuous operation of the chimney fan at temperatures up to 500°C. Peak load (up to five minutes) with temperatures up to 700 ̊C are possible with the RSHT. The chimney fan is part of an exodraft system and must be connected to an exodraft control. See below for matching accessories.
Product | Rev / min. | Voltage | Amp | kW | Weight | Capacity |
---|---|---|---|---|---|---|
RSHT009 | 1400 | 1 x 230 V | 0,4 A | 0,09 | 12 kg | Up to 400 m³/h |
RSHT012 | 1400 | 1 x 230 V | 0,6 A | 0,13 | 15 kg | Up to 800 m³/h |
RSHT014 | 1400 | 1 x 230 V | 1,2 A | 0,29 | 19 kg | Up to 1,300 m³/h |
RSHT016 | 1400 | 1 x 230 V | 1,8 A | 0,37 | 22 kg | Up to 2,350 m³/h |
The RSHG was intentionally designed for individual gas-fired boilers and gas fireplaces.
The chimney fan discharges horizontally and has a monitoring system integrated into it, which allows flow and pressure to be regulated with a switch.
The RSHG is placed above the chimney and offers a regulated vacuum that accommodates chimneys of any size, location, or height. Both existing and new chimney installations can accommodate the fan. The RSHG is an aspect of an exodraft system and needs to be connected to an exodraft control of EDC25 or EFC21. Matching accessories are listed below.
Product | Rev / min. | Voltage | Amp | kW | Weight | Capacity |
---|---|---|---|---|---|---|
RSHG012 | 1400 | 1 x 230 V | 0,4 A | 0,03 | 14 kg | Up to 625 m³/h |
RSHG014 | 1400 | 1 x 230 V | 0,4 A | 0,04 | 18 kg | Up to 900 m³/h |
The RSVG was intentionally designed for individual gas-fired boilers and gas fireplaces.
The chimney fan discharges vertically and a monitoring system is integrated into it, allowing you to regulate the flow and pressure.
The RSVG is placed above the chimney and offers a regulated vacuum no matter where the chimney is located or how big or tall it is. Both existing and new installations can accommodate the chimney fan.
The RSVG is a component of the exodraft system and needs to be connected to an exodraft control of EFX25 or EFC21. Matching accessories are listed below.
Product | Rev / min. | Voltage | Amp | kW | Weight | Capacity |
---|---|---|---|---|---|---|
RSVG200 | 1400 | 1 x 230 V | 0,4 A | 0,07 | 18 kg | Up to 1,100 m³/h |
RSVG250 | 1400 | 1 x 230 V | 0,8 A | 0,16 | 27 kg | |
RSVG315 | 1400 | 1 x 230 V | 1,8 A | 0,37 | 37 kg | Up to 3,000 m³/h |
The RHG160 is a chimney fan that can be used in conjunction with smaller gas fireplaces. The chimney fan discharges horizontally and contains an integrated monitoring system, which includes a flow meter and pressure control switch.
The RG160 chimney fan provides maximum chimney draft no matter the chimney’s size, location, or height. Existing and current installations can reap the benefits of this solution. The chimney fan is part of an exodraft system and has to be connected to an exodraft EFC25 or EFX21 control. See matching accessories below.
Product | Rev / min. | Voltage | Amp | kW | Weight |
---|---|---|---|---|---|
RHG160 | 1400 | 1 x 230 V | 0,4 A | 0,09 | 10 kg |
An exodraft chimney fan RSG offers negative pressure across the total diameter of the chimney and flue, which can be regulated.
The fan is equipped with a failsafe system that automatically measures the flue gasses’ speed. When the acceleration surpasses the safe and preset level, the gas appliance is ready for use. The failsafe system stops the gas appliance from spilling anything and prevents any poisonous gasses or CO from leaking out.
The external wall is where the fan type RSG is mounted. The fan allows a gas appliance to be installed in a chimney-less room. The fan’s power will permit horizontal flues to a maximum length of 15 metres.
Product | Rev / min. | Voltage | Amp | kW | Weight | Capacity |
---|---|---|---|---|---|---|
RSG125 | 1400 | 1 x 230 V | 0.3 A | 0.04 | 11 kg | Up to 150 m³/h |
RSG150 | 1400 | 1 x 230 V | 0.1 A | 0.05 | 14 kg | Up to 275 m³/h |
RSG200 | 1400 | 1 x 230 V | 0.4 A | 0.11 | 20 kg | Up to 575 m³/h |
RSG250 | 1400 | 1 x 230 V | 0.8 A | 0.14 | 31 kg |
The exodraft GSV chimney exhaust fan discharges vertically. Since the fan is installed above the chimney, it creates a vacuum in both the chimney and the flue pipe. The GSV is developed for applications where a vast amount of fat is used and where regular maintenance is needed.
The motor is an asynchronous motor which is heat-resistant, variable-speed, class H insulated. It has permanently lubricated and sealed ball bearings and is maintenance free.
For fat drainage, the GSV comes equipped with a pipe and unique base. As such, the extra fat from the chimney fan is directed into a collection tray (which you can purchase as an accessory) or another collection device.
The GSV chimney fans are aimed so that they are suitable for continuous use at temperatures up to 250°C.
The GSV chimney fan is a part of an exodraft system and must be combined with an exodraft control.
A special cooling vane and air slots ensure cooling of the motor as long as the fan is running.
The cable is high temperature resilient and pressure released and protected by a reinforced hose.
All of these functionalities give the chimney fan high operational reliability and a long service life.
Product | Rev / min. | Voltage | Amp | kW | Weight | Capacity |
---|---|---|---|---|---|---|
GSV315 | 1400 | 1 x 230 V | 1,8 A | 0,37 | 37 kg | Up to 3,000 m³/h |
GSV400 | 1400 | 1 x 230 V | 2,9 A | 0,37 | 47 kg | Up to 4,400 m³/h |
A Draftbooster chimney fan ensures that your wood-burning stove or fire can be lit without problems to provide good and environmentally friendly combustion, just as putting more wood into the stove can be done with no problems, minimising smoke in the room.
A Draftbooster chimney fan reduces particles and smoke in the room as well as soot deposits on the windows of the wood-burning stove.
Installation is extremely easy and can be done without skilled assistance.
The Draftbooster chimney fan can handle a constant smoke temperature of up to 250°C.
A Draftbooster is durable, reliable and corrosion resistant.
It is easy to clean and maintain.
Draftbooster chimney fans can be installed on both metal and brick chimneys.
Draftbooster chimney fans can be turned off at any point – even when a fire has been established in the stove/fireplace.
Specifications: |
---|
Click here to view technical specs. |